- * Abaton SCAN 300/FB (Ricoh IS30-M2) *
- * scanner command sequence codes. *
- *------------------------------------*
- * March 5, 1999 *
- *------------------------------------*
-
- NOTES:
- (1) The purpose of some commands are not yet known.
- (2) It appears that the scanner can have a Normal and Alternative mode.
- The Alternative mode, entered with an IS20 command, modifies
- the behavior of some commands. The purpose of this mode is not
- yet known.
- (3) <ESC> = $1B, <CR> = $0D
-
- ------------------------
- Command sequence example
- ------------------------
-
- ASCII: <ESC>!OB<CR>
- Hexadecimal: $1B $21 $4F $42 $0D
-
- -----------------
- Command sequences
- -----------------
-
- <ESC>!MT<State><CR>
- Unknown. If <State> = S, image is slightly fuzzier than normal, and the
- number of stray dots increases.
-
- <State> can be:
- S Enables mode.
- R Disables mode.
-
- <ESC>!RF<State><CR>
- Reflect the image about the Y-axis.
-
- <State> can be:
- S Reflected image.
- R Normal image.
-
- <ESC>!IV<State><CR>
- Normal or Inverted image.
-
- <State> can be:
- S A '1' in the image data is a light area.
- R A '1' in the image data is a dark area.
-
- <ESC>!TO<Length><CR>
- TimeOut handshaking delay for data transmission. Selection occurs
- for scanner to host transmission. Not known if used in the other
- direction as well.
-
- <Length> can be:
- S Short timeout delay.
- R Long timeout delay.
-
- <ESC>!DN<Density><CR>
- Set scan density. This command must be issued before any page-size
- commands, since the scanner uses the density to calculate the scan
- area.
-
- In Normal mode, <Density> can be:
- 300 300 dots per inch.
- 240 240 dots per inch.
- 200 200 dots per inch.
- 180 180 dots per inch.
-
- In Alternative mode, <Density> can be:
- 8 RD command value is 0.0270" per unit.
- 6 RD command value is 0.0313" per unit.
- 4 RD command value is 0.0388" per unit.
-
- <ESC>!LV<Level><CR>
- Sensitivity (or threshold) level affects scanner's response to image
- variations.
-
- <Level> can be:
- H High preset level (From 11 to 15).
- M Normal preset level (From 8 to 10).
- L Low preset level (From 0 to 7).
- 0 to 9, A to F 0 to 15 level (0 is the lowest).
-
- <ESC>!RD<Size><CR>
- Set page size dimension, and begin scanning area.
-
- (1) Change scan bar position.
- (2) Turns on the lamp.
- (3) Returns control to the host, but remain busy.
-
- <Size> can be the following:
- A4 - 210mm x 297mm
- A5 - 210mm x 150mm
- B5 - 176mm x 250mm
- B6 - 176mm x 125mm
- LT - 8.5" x 11.0" (Letter)
- 14 - 8.5" x 14.0" (Legal)
- AT - 8.1" x 14.0"
- CD - 3.5" x 2.0" (Business Card)
-
- <Size> can also be a numerical expression (BX+BW,PY+PH)
- BX Horizontal byte (8 pixels per byte) offset from origin.
- BW Number of bytes per row (8 pixels per byte). Must be >= 5.
- PY Vertical pixel offset from origin. Scanner bar position will
- change to (Y / DPI) inches.
- PH Number of pixel rows. Must be >= 1 in Normal mode, but >= 5
- in Alternative mode.
-
- Returned sequence will be:
- $01 $00 $01 - First section header.
- <Dots per inch> - Three ASCII digits (eg. '300' for 300 dots per inch).
- <Bytes per row> - Four ASCII digits (eg. '0025' for 25x8 pixels).
- <Total rows> - Five ASCII digits (eg. '03260' for 3260 rows).
- $00 $00 $02 - Second section header.
- <Scan data> - One byte = 8 pixels.
- $62 $62 $79 $D9 - Terminator ($62 $62 $79 $D8 also possible).
-
- If the host does not begin reading data within 15 seconds, the scanner
- will abort the command, and become ready.
-
- <ESC>!DA<Size><CR>
- Set page size dimension, but don't start scanning. <Size> is the same
- as RD command.
-
- <ESC>!RA<CR>
- Begin scanning the currently set area, such as from a previous DA command.
-
- (1) Move to beginning of scan area.
- (2) Turn on light.
- (3) Return control to host.
- (4) Wait for 15 seconds for the host to read the data.
- (5) Turn off light.
- (6) Home scanner bar.
-
- <ESC>!IT<CR>
- (1) Turn on light.
- (2) Home scanner bar.
- (3) Move to position zero.
- (4) Turn off light.
-
- <ESC>!HP<CR>
- Move the scanner bar to its Home Position (outside optical boundary).
-
- <ESC>!OB<CR>
- Move the scan bar to scan line zero (Optical Boundary).
-
- <ESC>!DS<CR>
- Stepper motor Driver Switch off. Power is removed from the motor
- (via an relay), perhaps for power savings. Any commands that requires
- the motor wil turn the power back on.
-
- <ESC>!FL<State><CR>
- Flourescent Lamp control. Lamp will turn off automatically in about
- 15 seconds.
-
- <State> can be:
- H Turn lamp on.
- L Turn lamp off.
-
- <ESC>!IS20<CR>
- Resets scanner (similar to when first powered up), and enters the
- Alternative mode.
-
- <ESC>!RS<CR>
- Similar to IS20 command, but can only be issued while in Alternative
- mode.
-
- <ESC>!VR<CR>
- Returns the scanner's version number (eg. '54997203D').
-
- <ESC>!MR<CR>
- Unknown. Returns one value.
-
- <ESC>!SR<CR>
- Unknown. Returns one value.
-
- <ESC>!PR<CR>
- Unknown. Returns five values.
-
- <ESC>!RI<Expression><CR>
- Unknown.
-
- <Expression> has the form (W,X:Y,Z), where the letters represent
- numbers. Number Y can have 5 digits. In Alternative mode, a
- semicolon must be used in place of the colon.
-
- <ESC>!OR<CR>
- Unknown.
-
- <ESC>!TS<CR>
- Identical to the 'OR' command.
-
- <ESC>!DE<CR>
- Unknown.
-
- (1) Switch off power to the stepper motor.
- (2) Return control to the host.
- (3) Remains busy forever.
-
- <ESC>!DM<Type><CR>
- Unknown.
-
- <Type> can be:
- A
- B
-
- <ESC>!BS<CR>
- Unknown
-
- <ESC>!BK<CR>
- Unknown
-
- <ESC>!ST<CR>
- Unknown
-
- <ESC>!MV<CR>
- Unknown
-
- <ESC>!BN<CR>
- Unknown
-
- <ESC>!HF<CR>
- Unknown
-
-